Everything You Need to Know About Building A Cleanroom: ISO Class Prefab Hardwall Cleanroom Design. Advantages for Modular Hardwall Design and Construction of ISO 14644-4 Cleanrooms.

  • Establishes a Controlled Environment: Hardwall cleanroom wall panels and components are engineered to provide a secure, controlled environment within the cleanroom.
  • Progressive Design: As needs change, modular cleanroom wall panel designs offer the ability to relocate or expand the cleanroom in the future.
  • Special Cleanroom Panel Sizes: Wall panels can be made in special sizes for entry areas, gowning rooms, and air-locks, ensuring that the cleanroom pressure remains constant. Extra-high, wall panel systems can accommodate large equipment which can require ceilings higher than the standard eight feet.
  • Load Considerations: Load-bearing cleanrooms require consideration of three factors for construction. The first factor is the amount of total weight on the cleanroom wall, the second factor is the span distance between all four of the cleanroom walls and the third factor is the height of your wall.
  • Once Through Design: Ambient air is drawn into the fan filter unit at the ceiling level. The filtered air passes into the cleanroom and is transferred out of the room through grilles at the bottom of the walls.
  • Recirculating Design: Recirculating cleanrooms are ideal when temperature or humidity control is required.

Elements of Modular Hardwall Cleanroom and Partition Construction

  • Cleanroom Wall Material: Prefab cleanroom wall panels find favor in quick turn cleanroom construction, but custom built modular wall panels continue to grow in popularity. Self-supporting walls increase design freedom for both large and small installations. Notably, fire and soundproof wall panels with polystyrene cores provide excellent thermal insulation and sound deadening properties.
  • T-Grid Ceiling System: Cleanroom T-grid systems support the integration of lighting, diffusers, tiles, and other integrated design features. These systems include all connectors, suspension hardware and gaskets which are then applied on site.
  • Ceiling Support Structure: Suspension support beams attach to the top of modular cleanroom walls for suspending a T-Grid Ceiling System. The sturdy structure removes the need for support from the host building.
  • Cleanroom Ceiling Tile Grid Systems and Panels: Ceiling panels with sealed edges for spaces provide particulate control in spaces not occupied by fan filter units or light fixtures.
  • Cleanroom Lighting: Cleanroom light fixtures are common in 2′ X 4′ configurations. 4-lamp cleanroom light fixtures with energy-efficient T8 electronic ballasts provide flicker-free startup and better overall efficiency. Cleanroom lights feature sealed housings and low profile, recessed construction for minimal particle retention and easy wipedown.
  • Cleanroom Pass-Thrus: Pass-thru cabinets allow you to move a product from one environment to another without affecting the cleanliness levels in your cleanroom.
  • Cleanroom HEPA Filters: Standardized cleanroom are commonly sized in 2′ x 4′ units with options for 115V (60 Hz), 208-230V (50/60 Hz), and 277V (60 Hz). 99.99% HEPA filtration is supported by variable speed control and all other standard specifications. The average cost of a HEPA filter unit for cleanroom specifications varies with cleanliness requirements and amount of air changes per hour. Getting a free quote is always an option.
  • Guidelines for selecting HEPA Filter Units (FFU): Sometimes getting help making the calculations necessary to achieve the desired ISO or U.S. Federal Standard 209 Class is essential. The correct quantity of HEPA or ULPA grade filters will be selected using air changes per hour as the most effective method for meeting class requirements.
  • Cleanroom Monitoring, Testing, and Validation Systems: Particle monitoring systems provide sophisticated computer-based monitoring systems for critical applications. They are ISO-9001/2008 certified, and the development processes meet cGMP standards. In addition to SCADA and general process control systems, there are over 200 systems installed in hospitals, clinics, and laboratories as well as pharmaceutical manufacturing operations throughout the world.

Cleanroom Validation and Classes

How Are Cleanroom Standards Determined?
The number and size of particles allowed in the room determine the classification of air cleanliness. See the ISO standards table for cleanroom classification requirements related to your application.

 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award