CLIN
  •   
  •   +6(04) 398 1778
Cleanroom Maintenance

Cleanroom Maintenance

Regular maintenance procedures-daily, weekly, monthly, and quarterly-help ensure cleanroom compliance, no matter what the cleanroom class. For example, positive-pressure air should be running at full-flow in a Class 10 cleanroom for at least 30 min before cleaning to ensure clean, fresh air within the room. Cleaning starts at the highest point and works toward the floor. Every surface, corner, and ledge are first vacuumed, then damp-wiped with a cleanroom wipe. Operators wipe surfaces one way-either downward or away from themselves-since a "back-and-forth" scrubbing motion can create more particles than it removes. They also use a clean surface of the wipe or sponge with every new stroke to guard against redeposition of contaminates. On walls and windows, the wiping movement must be parallel to the airflow.

Floors are neither waxed nor buffed (materials and processes that contaminate the room), but are cleaned with a DI water and isopropyl alcohol mixture.

Cleanroom equipment maintenance also requires special procedures. For example, to prevent the spread of grease and to contain its airborne molecular contamination (AMC), equipment needing lubrication is isolated with polycarbonate shields. A fully gowned maintenance worker wears three pairs of latex gloves to perform this maintenance. After greasing equipment, the maintenance worker removes the outer glove, turning it inside out under the shield to contain the grease. If this procedure is not followed, the maintenance representative could leave grease on the door or other surfaces while leaving the cleanroom, and all operators who subsequently touched that doorknob would spread the grease and organic contaminates.

Some specialized cleanroom equipment also must be maintained, including HEPA filters and ionizing grids. Vacuuming HEPA filters every 3 mo removes particles. Recalibrating and cleaning ionizing grids every six months ensures the proper ion release rate. Cleanrooms should be reclassified every 6 mo by confirming that the air particle count meets the cleanroom class designation.

Useful tools in contamination detection are air and surface particle counters. Air particle counters can check contaminant levels at set intervals or around-the-clock at varied locations. Particulate levels should be measured at activity centers where products would be-at tabletop height, near conveyors, and at workstations, for example.

Surface particle counters should be used to monitor operator workstations. If a product breaks, the operator can use this device after a cleaning procedure to determine if additional cleaning is needed. Air pockets and crevices where particles can collect should be given special attention.

 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award