Clean Room: Contamination Control
Contamination control is being used by more and more industries where the highest level of cleanliness and hygiene is of vital importance. These are the things that need to be considered when building an effective contamination control room.
- HEPA (High Efficiency Particulate Air Filter) - These filters are extremely important for maintaining contamination control. They filter particles as small as 0.3 microns with a 99.97% minimum particle-collective efficiency.
- Clean Room Architecture - Clean rooms are designed to achieve and maintain an airflow in which essentially the entire body of air within a confined area moves with uniform velocity along parallel flow lines. This air flow is called laminar flow. The more restriction of airflow the more turbulence. Turbulence can cause particle movement.
- Measurement and Instrumentation - Some important measurements related to contamination control are particle count, air flow & velocity, humidity, temperature and surface cleanliness. Clean room managers usually have specific standards and/or instruments to measure these factors.
- Electrostatic Discharge (ESD) - When two surfaces rub together an electrical charge can be created. Moving air creates a charge. People touching surfaces or walking across the floor can create a turbo-electric charge. Special care is taken to use ESD protective materials to prevent damage from ESD.
- Cleaning managers should work with their personnel to understand where these conditions may be present and how to prevent them
- Ventilation and Makeup Air- Ventilation and makeup air volumes are dictated by the amount required to maintain indoor air quality, replace process exhaust and for building pressurization.
- Pressurization- Rooms in a clean facility should be maintained at static pressures higher than atmospheric to prevent infiltration by wind. The only exception to using a positive differential pressure is when dealing with specific hazardous materials where governmental agencies require the room to be at a negative pressure.
- Temperature and Humidity- Temperature control is required to provide stable conditions for materials, instruments, and personnel comfort. Humidity control is necessary to prevent corrosion, condensation on work surfaces, eliminate static electricity, and provide personnel comfort.
Resources & Articles
CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.
Content Disclaimer
Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.
In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.
Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.
Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.