Choosing the correct door system is a major factor in ensuring the delicate balance of a cleanroom. If the doors do not function properly, the cleanroom could fail to meet relevant cleanroom standards and be exposed to a higher risk of contamination. Here are some of the most basic but essential factors to consider when selecting a cleanroom door.

Hygienic & Flush Fitting

It’s vital that doors and frames are completely flush with the wall panels in order to meet compliance standards and be easy to keep clean. The door surface should also be a smooth flat surface that is free from ledges, recesses or anywhere that bacteria or dust particles that can be trapped and grow. Vision panels within the doors should also be completely flush to the door to maintain hygiene. As ISO-1464 44-4 2001 states: “Doors should present as few horizontal ledges as possible with particular attention being paid to the minimisation of steps or ledges.”

Easy to integrate

Door systems which are designed to be compatible to any type of wall system should be chosen. It is essential that the complete door and frame system can be integrated seamlessly to create a flush finish on both sides of the wall. If the door system does not integrate into any wall structure then it can be difficult to change parameters within the facility without the cleanroom door integrity being compromised.

Resistant to cleaning chemicals

Cleanrooms are exposed to intense cleaning every day with a variety of strong chemicals to assure high levels of hygiene. Cleanroom doors, as any other cleanroom surfaces, need to be resistant to the regular usage of any cleaning products and any reaction between the door and the chemicals need to be avoided. Most reputable companies carry out tests to make sure doors resist common cleaning chemicals, Chlorine and VHP (vaporised hydrogen peroxide).

Easy to keep clean

Door surfaces in a cleanroom should be smooth in order to remain impervious to microorganisms. The design of cleanroom doors should be kept as simple as possible, avoiding the use of elements that are difficult to clean like ledges or complex mechanisms. Both sides of the door and frame should be completely flush to the wall, to avoid uneven surfaces which are difficult to keep clean.

Impact resistant and durable

Doors in cleanrooms can be subject to high amounts of traffic and exposure to hazardous chemicals on a daily basis. Selecting the right door solutions can help save time and money over the longer term. Strong, lightweight doors should be chosen to improve durability, ease of maintenance and low lifecycle costs.

Vision panels with safety glazing

In a cleanroom, safety comes first. Therefore, every part of the product should be designed to meet the highest safety requirements. Vision panels in doors should be safety glazing and shatter proof to prevent any risk of glass scattering if the panel breaks.

 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award