In a nutshell, if you manufacture a non-sterile medicinal product, you should be very careful about classifying or grading your clean areas, for example, classifying a room as “Grade D”. Whilst not a code requirement, many regulators, like the Australian TGA will expect you to fully comply with all of the requirements for a Grade D room as defined in Annex 1, even if it’s not a GMP code requirement. If you have classified the room as Grade D, you will need to live with the consequences and costs of maintaining this level of clean room cleanliness during operation.
What type of Clean room do I need?
If you are a manufacturer of non-sterile medicinal products, you should define your own cleanroom / area standards using national and international standards. Usually manufacturers will define an airborne particulate concentration standard class such as ISO 14644-1 ISO 8 (at rest), outline gowning and a pressure cascade regime, defining a “clean corridor” design or a “dirty corridor” design.
If you are a manufacturer of sterile medicinal products, you must follow the EU or PIC/S GMPs, namely Annex 1.